Percutaneous intervention for Optitorque tiger catheter-induced dissection of the right coronary artery and aortic root


Sheshagiri Rao Damera, Ramachandra Barik, Akula Sivaprasad 
 Department of Cardiology, Nizam's Institute of Medical Sciences, Hyderabad, Telangana, India

Correspondence Address:
Ramachandra Barik
Department of Cardiology, Nizam's Institute of Medical Sciences, Hyderabad - 500 082, Telangana
India

A 59-year-old female developed iatrogenic Type F spiral dissection of the right coronary artery (RCA) with retrograde extension as Type III aortic dissection (AD) during diagnostic coronary angiogram using 5 Fr Optitorque Tiger catheter. The spiral dissection of RCA was treated with angioplasty. AD was followed up with conservative management. The prompt identification of the starting point, the true lumen, and exit point of the dissection is the keys to the successful percutaneous revascularization. Visual eyeballing into multiple angiographic views is of immense help in the situation where optical coherence tomography and intravenous ultrasound are not available.


How to cite this article:
Damera SR, Barik R, Sivaprasad A. Percutaneous intervention for Optitorque tiger catheter-induced dissection of the right coronary artery and aortic root.Nig J Cardiol 2017;14:31-34


How to cite this URL:
Damera SR, Barik R, Sivaprasad A. Percutaneous intervention for Optitorque tiger catheter-induced dissection of the right coronary artery and aortic root. Nig J Cardiol [serial online] 2017 [cited 2023 Mar 23 ];14:31-34
Available from: https://www.nigjcardiol.org/article.asp?issn=0189-7969;year=2017;volume=14;issue=1;spage=31;epage=34;aulast=Damera;type=0